The purpose of these assays was to establish a proof-of-concept for the LFIA test, demonstrating that these conjugates are indeed capable of functioning as anti-P. To achieve this goal, AuNP-RSA conjugates were incubated with human serum before and after treatment with BSA and casein , which are two non-antibody-reactive blocking agents that are usually applied as immunoassay blockers . This step was performed to ensure blockage of non-specific binding sites available on the surface of AuNPs after saturation with the RSA, so that non-specific interactions between AuNPs and serum proteins were minimized. For both AuNP-RSA conjugates, casein proved to be the most effective blocking agent, reducing non-specific interactions between human sera and those conjugates . However, even in the presence of a pre-blocking step with casein, there is some residual interaction between the negative serum and the conjugates .

The infected sample was positive with low signal intensity, and it was correctly classified as RGNNV. The genotype strip cutter of the sample was previously determined by direct sequencing by an independent research group. Optimization studies for assessment of the oligonucleotide probe impact in the hybridization reaction mixtures were performed. The oligonucleotide probes were tested in amounts of 0.5–4 pmol/1 pmol of target (Figures 4 and 4). Both test zones resulted in optimum signals when 1 pmol of probe was used and decreased with higher amounts of probe. When higher amounts of biotinylated probes are used, the amount of nanoparticles that bind to the free probe is increasing. Even though these nanoparticles move along the LFB, they cannot be immobilized from the deposited antibodies in the test zones, and the red bands become fainter .

The anti-digoxigenin antibody performance for test zone construction was evaluated in the previously mentioned study , as well as other independent studies . Therefore, the same type of anti-digoxigenin antibody was utilized for the TZ-S construction in the present study. However, the use of the polyclonal fluorescein antibody for the construction of TZ-R zone was only evaluated in our previous study.

Reporter Nanoparticle Selection For Lateral Flow Immunoassays

As a result, there was accumulation of gold nanoparticles and generation of a characteristic red line at the proper test zone of the biosensor. The excess nanoparticles were captured from immobilized biotinylated BSA at the control zone of the LFB, hence generating a red line that confirmed the proper function of the biosensor. The biosensor detects only the short, genotype-specific PCR products and not the long ones. The latter hybridizes to both probes but is not captured at the test zones since it lacks a labelled end . The presence of an anti-fluorescein red zone (TZ-R) and absence of an anti-digoxigenin red zone indicated the RGNNV genotype. The SJNNV genotype was characterized by a red zone of anti-digoxigenin (TZ-S). Theoretically, presence of both genotypes in a sample would result in red zones for both immobilized antibodies.

Monodispersed production of AuNPs with adequate size was confirmed by UV/Vis spectrophotometry (Thermo Scientific™ Evolution 60S). Spherically shaped (ca. 40 nm in diameter) and deep red colored AuNPs were synthesized. The size of these unmodified AuNPs was estimated by using the Beer–Lambert law at 530 ± 2 nm and transmission electron microscopy (Fig. 2) (JEOL Ltd. JEM-1011).

Custom nanoparticle modifucations are also available upon request for assay development and optimization. immunochromatographic assays, and rapid strip tests) are a user-friendly test format designed to detect the presence or absence of a target analyte within a sample. They can detect a wide variety of pathogens, drugs, hormones, metabolites, and other molecules from biological and chemical samples. Kit for passive adsorption of antibody and protein to 10 nm gold nanoparticles. Kit for passive adsorption of protein to 40 nm and 60 nm gold nanoparticles for lateral flow applications. Kit contains buffers and 100 mL each of 40 nm and 60 nm gold nanoparticles.

Preparation Of Lfa Strips

After 30 min of the reaction, the resulting 10-nm GNPs were centrifuged at least thrice at 20,000 g for 60 min. Finally, 10-nm GNPs were resuspended in 10 mL of 0.1 M CTAC. Then, these 10 nm GNPs were overgrown to a designed size. To this end, 0.1 M CTAC, 10 mM AA and the 10-nm GNPs were mixed, as indicated in Table 2, in a 200-mL flask. Further, 2 mM HAuCl4 was added by using a syringe pump at the injection rate 10 mL/h.

  • Han X., Li S.H., Peng Z.L., Othman A.M., Leblanc R. Recent development of cardiac troponin I detection.
  • Monodispersed production of AuNPs with adequate size was confirmed by UV/Vis spectrophotometry (Thermo Scientificâ„¢ Evolution 60S).
  • To accelerate migration of the samples through the strip, we used cellulose fiber as an absorbent pad pasted on the backing card opposite the conjugate pad.
  • The assay employs both biotinylated anti-norovirus antibodies and gold-labeled anti-norovirus antibodies; when target noroviruses are present in the sample, virions associate with the antibodies while flowing through the strip.
  • However, such improvements result in the loss of the main advantage of LFIA as a simple point-of-care test.

On the other hand, we recently demonstrated that increasing the nanoparticle size up to 115 nm reduced the LoD . Moreover, conclusions about the capabilities of a label can be made only by comparing the analytical characteristics achieved for its conjugates with antibodies of different compositions . However, changes in the antigen-binding properties of antibodies with variation in their surface density on a nanoparticle are nontrivial and, to date, have not been described by a single, universally recognized model. For example, the curvature of the nanoparticle surface can play an important role in the affinity of the GNP–antibody complex . The results from Figures 6A,C show that visually the test and control lines became easier to see with the naked eye and the results from Figures 6B,D confirmed this by color quantification.

Alexandria Engineering Journal Impact

Encouraged by the improved optical property, we investigated the feasibility of the customized GSPs in highly sensitive colorimetric detection. In this case, the GSPs were utilized as visual contrast labels in LFIA strip. HCG, a key diagnostic marker of pregnancy and an important risk biomarker of certain diseases, was selected as a model analyte .

After reaction for 90 min at room temperature, BSA was added into the above mixture solution and allowed to react for 1 h to block the unreacted carboxyl group. The resulting GSP270 probes were then purified via centrifugation; resuspended PB solution (200 μL, 0.01 M, pH 7.4) containing 25% sucrose, 1% BSA, and 0.1% sodium azide; and stored at 4 °C for subsequent use. Summary of the detection performance of AuNP- and GSP-LFIA strip in detecting HCG. The theoretical Optical performance of GSPs and AuNPs; The illustration of sandwich LFIA platform; The detection sensitivity of GSP-LFIA and AuNP-LFIA.

Despite the worse sensitivity than chromatograph strips, LFSA would be a promising method in point-of-care testing field. By applying above labels, lateral flow assays are rapid, simple, allowing point-of care testing. Due to these features, they were commercialized and used in the field of health. The following advantages also explain their success in clinical diagnostics.

Analysis Of Human Sera Interaction With Aunp

Jans H., Huo Q. Gold nanoparticle-enabled biological and chemical detection and analysis. The compositions of all these factors show the need for more experimental studies. The identified regularities are impossible for prognostic assessment of the reactivity of conjugates and LODs achieved with their help. The best variants for both GNPs demonstrate a significant increase in sensitivity . Thus, the proposed new immunochromatographic label provided an 8-fold improvement in assay sensitivity.

To demonstrate the versatility of our strategy, we further extended the GSP-LFIA strip for the sensitive detection of HBsAg, an important serological biomarker for hepatitis B virus infection diagnosis . In this case, GSP270 was selected as visual label for the fabrication of GSP270-LFIA strip because GSP270 possesses large optical absorbance and good diffusivity on the NC membrane. For direct comparison, the AuNP40-LFIA strip was developed at the same time. Several key parameters that influence the sensitivity of AuNP40-LFIA and GSP270-LFIA strip were systematically investigated and optimized .

Zheng Y., Zhong X., Li Zh., Xia Y. Successive, seed-mediated growth for the synthesis of single-crystal gold nanospheres with uniform diameters controlled in the range of 5–150 nm. Zhang W.J., Duan H., Chen R., Ma T.T., Zeng L.F., Leng Y.K., Xiong Y.H. Effect of different-sized gold nanoflowers on the detection performance of immunochromatographic assay for human chorionic gonadotropin detection. Xu P., Li J., Huang X.L., Duan H., Ji Y.W., Xiong Y.H. Effect of the tip length of multi-branched AuNFs on the detection performance of immunochromatographic assays. Shiba F. Size control of monodisperse Au nanoparticles synthesized via a citrate reduction process associated with a pH-shifting procedure. Zhan L., Guo S.Z., Song F.Y., Gong Y., Xu F., Boulware D.R., McAlpine M.C., Chan W.C.W., Bischof J.C. The role of nanoparticle design in determining analytical performance of lateral flow immunoassays. Tassa C., Duffner J.L., Lewis T.A., Weissleder R., Schreiber S.L., Koehler A.N.,

Like it? Share it!