Industrial silencer
Posted by Thomas Shaw on June 4th, 2019
When one is planning to a noise reduction by the signifies of a silencer, ITS offers a wide selection of industrial silencers for a lot of applications connected to acoustic insulation / soundproofing connected for the protection of workers against noise, the preservation of acoustic atmosphere, the limitation of noise emissions in the energy sector, the acoustical behavior of testing rooms, the acoustic comfort in industrial buildings. Get additional information about industrial silencer
Array of applications
reduction of sound transmission within a duct, a pipe or an opening, with no preventing the fluid transportation
industrial silencers may be inserted into aeraulics networks, specifically for the inlet or outlet of ventilation or air conditioning systems e.g. climate control, refrigeration, cooling (if expected: with towers) but in addition for the soundproofing of fans e.g. oven for heavy business, fumes treatment course of action, and also of compressors, of heat engines and combustion turbines (for the diminution of noise emitted by air intake and exhaust for energy generation)
industrial silencers could be inserted into pressurized fluid networks e.g. to limit the noise of control valves (in-line silencers) or to reduce noise emissions during depressurization (discharge expansion) e.g. tank drain, bleed, valve
Benefits
fantastic technical traits and robustness
ease of implementation (easy assembly/disassembly)
high adaptability of acoustic overall performance
wide range of probable applications such as reduction of noise emitted by gas turbine air intakes, inlet (resp. outlet) of cooling towers, of cooling systems, of aerocondensers, of chillers, of air conditioners, of heat pumps ... and noise reduction (notably: mouth noise) of smoke evacuation ducts (stacks, flues for test rigs, exhaust ducts ...)
Presentation :
envelope generally rectangular (sometimes circular in case of silencer for air ducting operates by way of example), metallic, single or double shell (best mechanical resistance more than time) if required with an upstream connecting flange and having a downstream connecting flange and ( for some applications) with thermal, acoustic or thermoacoustic outer insulation. Plastic building possible for unique applications (e.g. in case of very corrosive fluid at low temperatures)
splitters (at times referred to as: baffles) commonly parallelepipedic (except for silencers having a circular cross section), with metallic frames and structures. Plastic construction possible for special applications (e.g. in case of quite corrosive fluid at low temperatures)
thickness, filling (generally mineral wool: polyester wool or other for specific applications), finishes, free open location, geometry of upstream and downstream ends: adapted based on the preferred performance