Centrifugal pumps combined with the installation and operation

Posted by uuuseff on November 18th, 2019

Centrifugal pump with a centrifugal pump combination 1, parallel operation of two models of the same pump in parallel, the characteristic curve can be synthesized using a single pump characteristic curve. When the pipeline characteristic curve is unchanged, the flow rate increases in parallel, but less than the sum of the two single-pump flow, that is, Q H. 2, series operation Two models of the same pump in series, the characteristic curve can also be used single pump characteristic curve synthesis. When the pipeline characteristic curve is unchanged, the indenter increases in series, but also less than the sum of two single-head pressure, that is, H series Q single. 3, the choice of combination If both ends of the pipeline () item value greater than the maximum pressure pump can provide, you must use the series operation. For low resistance type pipeline (that is, the pipeline characteristic curve is relatively flat), the flow and pressure head delivered by the parallel pump are larger than the series pump. For the high resistance type pipeline (that is, the pipeline characteristic curve is relatively steep), the flow and pressure head delivered by the tandem pump are larger than the parallel pump. Centrifugal pump installation and operation Centrifugal pump installation height should be less than the allowable installation height (ie, the calculated installation height), so as to avoid cavitation. In order to reduce the fluid resistance of the suction pipe, the suction pipe diameter should not be less than the diameter of the pump inlet. The suction pipe should be short and straight without a valve. However, when the suction inlet of the pump is higher than the liquid level, a reverse check valve should be added. Centrifugal pump should be filled with liquid before start-up, in order to avoid gas binding phenomenon; close the outlet valve to reduce the starting power. Centrifugal pump should be closed before the exit pump outlet valve. Centrifugal pump operation, the shaft seal should be regularly checked for leaks, bearings, stuffing boxes and other heating conditions, bearings should pay attention to lubrication.

Carbide Woodworking Tools

Carbide Screw Knives,Carbide Screw Blade,Carbide Screw Inserts

MoSi2 Heating Elements CO.,LTD , http://www.nsmolybdenum.com

Like it? Share it!


uuuseff

About the Author

uuuseff
Joined: November 10th, 2018
Articles Posted: 183

More by this author