cooling-towers

Posted by dama goostar on November 26th, 2020

Cooling tower ( or cooling tower modification ) is a water cooling machine, which is also called "water cooling tower" . A cooling tower is a refrigeration machine that is typically used to reduce water temperature to a certain range. The reduction of water temperature in the cooling tower is naturally a function of the temperature conditions of the installation environment. This cooling machine ( cooling tower) absorbs the heat of the machines by water and directs it to the outside environment.

It is interesting to know that the heat absorbed by the industrial equipment in the internal mechanism of the cooling tower is transferred to the outside by dry air. In other words, the cooling tower is a type of energy exchanger between the climate, which is actually called a heat exchanger (heat exchanger). In fact, this refrigeration source exchanges heat energy by creating contact and collision between hot water and ambient air. Heat is exchanged from hot water to cool air, which reduces the water temperature.

Why do we use a cooling tower ??

The question may be, why do we use a cooling tower? In response, it should be stated that the cooling tower is complementary to every device and machine that is used in a specific direction. In fact, it should be said that every industrial machine and any device that is used heats up after a while. Air or water is used to cool all industrial machines such as chillers, boilers, etc. The water that absorbs the heat of an industrial machine is heated and needs a device to reduce its temperature again. In other words, the cooling tower (also known as the cooling tower) is responsible for re-circulating water to cool other devices.

*** Take a closer look at the operation of the cooling tower

The cold water produced in the cooling tower re-absorbs the extra energy of the equipment and frequently transfers it to the air. This process is an iterative cycle that keeps the operating temperature of industrial machinery constant Water cooling tower or cooling tower with continuous production of cold water can heat the chiller, boiler or induction furnace.

Permanent reduction of machine temperature and heat absorption of this equipment is required for system stability. Lack of cold water circulation will increase the temperature of these equipments and their inefficiency. Therefore, the need to use a cooling tower will stabilize the "system" with the highest efficiency. This system may be the air conditioning cycle of a residential, office or commercial building or the process of producing a particular product by an industrial machine.

Method of calculating the power or capacity of the cooling tower

The cooling tower's ability to dissipate heat energy from the water fluid and transfer it to the air is called refrigeration capacity or cooling tower capacity . The higher the refrigeration capacity of the cooling tower, the more water it will be able to bring to the desired temperature at a given time. The type of cooling fluid, the amount of fluid volume in rotation and the difference between the inlet and outlet temperatures of the fluid in the cooling tower are the main factors determining the capacity. The volumetric rate of circulating water is also called water flow rate. Of course, the ambient temperature factor, hot and cold water temperature are other factors involved in the design conditions. The difference between the inlet and outlet temperatures of the fluid is called the delta or range.

Characteristics that determine the capacity of the cooling tower

  • Circulating fluid flow rate (nominal fluid flow)

  • Type of coolant and determination of specific heating capacity

  • Fluid inlet and outlet temperature (outlet temperature depending on the design environment)

  • Coefficient of design effect in calculating nominal capacity and separating it from real power

Methods of calculating the cooling cpacity of the cooling tower

  •  Thermodynamic equations governing design conditions (q = m * c * delta T)

  • Calculation based on the capacity and type of chiller only in the use of chiller cooling

  • Use of cooling software cooling capacity calculation software

 

What is the meaning of refrigeration in the cooling tower?

You must have heard many times that the capacity of the tower is equal to 100 tons or the capacity of a specific model of chiller is equal to 200 tons. The word "ton" in the cooling tower and chiller means the same cooling capacity of the device in cooling water. The word body in this engineering term is abbreviated to "refrigeration body" or "cold body". Cooling is one of the heat transfer units and a measure of the power of refrigeration devices. The refrigeration ton thermodynamic unit (RT) is equivalent to units such as KW and BTU / H. Each ton of refrigerant is equal to 3.51 kW and is equivalent to 12,000 BTU per hour.


What is the use of a cooling tower?

1- In order to cool various industrial devices

Most industrial machines, such as furnaces, boilers, and turbines, generate some extra heat in their duty cycle. The functionin the cycle of these machines and equipment is to absorb and dissipate the excess heat generated. Gas turbines in refineries, air compressors in power plants and boilers in industry are among the most important cooling equipment with cooling towers. The task of extracting this thermal energy is the responsibility of the air fluid. The use of other refrigeration machines such as chillers is also common in small and large industries. High costs in energy consumption, difficult maintenance of chillers, has made the industry welcome the cooling tower.

2- To cool the air conditioning chillers of buildings in summer

Most large buildings and towers, offices, banks and shopping malls have central air conditioning (HVAC). Concentration or absorption chillers are used in central cooling systems to cool the indoor air. The heat absorbed from a building area by the chiller increases the temperature of this refrigeration machine. Cooling tower is used in this application under the name cooling tower with the aim of adjusting the chiller temperature The cooling tower generates cold water and directs it to the condenser, causing the temperature balance of this equipment. It should be noted that only chillers that have a water condenser use a cooling tower in their condenser circuit. Today, most compression chillers and all absorption chillers have a water condenser.


Types of cooling towers

  • Open Circuit Cooling Tower (Wet)

The open cooling tower reduces the water temperature by creating a direct contact exchange surface between air and water. In this cooling tower model, a percentage of water evaporates and enters the inlet air. This causes the surrounding air to become humid or saturated. For this reason, this model is also called the wet cooling tower  system The water coming out of the nozzle or sprinkler starts to fall on the packings in contact with the air and the temperature decreases. Wet systems are also called open circuits because the water cycle takes place in an open cycle.

  • Dry closed circuit cooling tower

In this cooling tower model, the water is cooled in a completely closed cycle (Close) in contact with the dry air of the environment. Hence, this type of refrigeration system is also called dry cooling tower . This type of cooling tower is subject to the noticeable temperature of the installation place (ambient temperature) due to direct contact with the dry air of the environment. Dry or closed cooling tower has heat transfer surfaces such as pipe and fan networks. Water passes through these networks in contact with the air created by the fan or impeller.

  • Hybrid cooling tower (hybrid)

The new generation of evaporative refrigeration equipment, which is a combination of open and closed The main stream of water fluid is passed through the thermal penetration surfaces of the coil by a secondary spray stream. In this contact, heat is transferred from the hot water of the coil to the cold water of the spray circuit by penetration and conduction. The big advantage of this cooling tower model is the reduction of water temperature to close to the humid ambient temperature. This refrigeration system, at the same time, has no fouling or evaporation.


Types of cooling towers based on the type of inlet air flow

  • Opposite flow cooling tower or counter flow

Canterflow cooling tower has air inlet from all sides of the device in the upper part of the pan and the lower part of the packings. The direction of the incoming air flow to in the opposite direction to the water flow from the nozzle. In this model, air enters from the lower louvers and exits from the upper part of the fan oven. The efficiency of this cooling tower model is very suitable for hot and dry environments. They are widely used in cities such as Yazd, Shiraz, Mashhad, Tehran, Arak and Isfahan where the relative humidity is low. Counterflow systems are more efficient than crossover systems. Of course, the use of these systems in humid and humid areas has little efficiency.

  • Cross-flow cooling tower or cross-flow

Crossflow tower or vertical flow has two main air inlets on both sides. The air entering this section perpendicular to the flow of water causes this fluid to cool.  performs well in sultry areas due to fresh air contact throughout Beijing In the northern and southern regions of our beloved country, which due to its proximity to the sea, the humidity of the environment where the cooling tower is installed is high. In such climatic zones, cross-flow cooling towers or Abara are used. Cities such as Ahvaz, Mahshahr, Bushehr, Rasht, Gorgan, etc. are very suitable for using this device. This model was first conceived by the Japanese company Abara. For this reason, such refrigeration systems are also called Abara cooling towers.

Internal and important components of the cooling tower

 

  • Electric motor: Provides the necessary torque to rotate the fan or mechanical energy generator

  • Fan: generates relative pressure in the air and displaces a certain volume of air fluid

  • Speed ​​reducer: Reduces the angular velocity of the motor (motor speed) to the standard fan rotational speed

  • Gearbox and speed reducer: Replaces the pulley belt system in power transmission from the alternator to the impeller

  • Cooling surfaces (fill): Filling or straw to create a direct heat transfer surface between the climate (in open circuit cooling towers)

  • Coil: Provides a surface for energy exchange between climates (in CCTV towers)

  • Nozzle: Divides the incoming hot water stream into cubic towers

  • Sprinkler: Hot fluid distributor in conical cooling towers

  • Pipe and fittings: Conveyor of water flow in the inner parts of the tower

  • Belt Fastener: Connecting internal branches to nozzles or nozzles

  • Drift eliminator: Inhibitor of dropping water droplets on the induction suction fan

  • Basin: A place where cold water is collected or a low-temperature water storage tank

  • Shutters (louvre): Valve for dry and cold air to enter the environment

  • Fan deck: Hot saturated air outlet

  • Panel: The main walls of the structure or body

  • Retaining or conservative supporters (supports): cans, packing holder, and other internal equipment

  • Fan Guard: Fan protector against possible shocks or the entry of foreign objects

  • Motor Chassis: Alternator or electric motor retaining frame

  • Inlet Flange: Hot water inlet connection

  • Outlet Flange: The location of the cold water outlet

  • Floater: Float that regulates compensatory water flow

  • Drain valve: blow down outlet

  • Overflow flange: the outlet for discharging excess water

Cooling tower control and side components

  • Variable speed control system (VFD control):

This part is responsible for manually or automatically adjusting the output speed of the motor by changing the frequency in the control panel.

  • Antifreeze in cold water storage pan (anti-freez):

It has two parts, heater and thermostat, which prevent the water from freezing by being placed in the pan in winter.

  • Lower fan deck:

This part is installed under the part of the between the fan and Foley and reduces the existing vibrations of the impeller.

  •  Mechanical shock absorber (spring shock absorber):

It causes vibration damping and reduces the vibration level of the cooling tower and is also widely used in various types of compression chillers.

  • Auto-drain system:

The smart blower is equipped with a TDS meter and solenoid valve, which reduces the amount of heavy salts in the pan.

  • Air filter system:

Metal air vents (aluminum) are installed behind the shutters to prevent suspended particles from entering.

  • Side glass or side panel:

Glass panel or perception that makes it easy for the operator to see the operating conditions of the cooling tower in different conditions.

  • Pump shower:

This part is only used in the hybrid cooling tower system and constantly sprays water on the coil.

  • Trash trap:

This equipment is installed in front of the cold water outlet flange and prevents the passage of debris in the pan.

  • Micron filter of compensating water circuit (bag filter):

The bag filter will increase the quality of the compensating water and reduce the amount of scale in the internal parts of the cooling tower.